3.5 Ton 15.2 SEER2 Goodman AC Split System GSXH504210+AMST42CU1400 (Not a Heat Pump)
Standard Features
• High-efficiency scroll compressor
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes,
refer to the Installation Instructions and/or the Long Line Set Applications guide.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
GSXH504210
Model | GSXH504210 |
Capacities | |
Nominal Cooling (BTU/h) | 42,000 |
SEER2 | 15.2 |
Decibels (dBA) | 72 |
Compressor | |
RLA | 177 |
LRA | 110.2 |
Stage | Single |
Type | Scroll |
Condenser Fan Motor | |
Motor Type | PSC |
Horsepower | 1/4 |
FLA | 1.30 |
Refrigeration System | |
Refrigerant Line Size ¹ | |
Liquid Line Size (“O.D.) | ⅜" |
Suction Line Size (“O.D.) | ⅞" |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜" |
Suction Valve Size (“O.D.) 2,3 | ⅞" |
Valve Type | Sweat |
Refrigerant Charge 4 | 177 |
Electrical Data | |
Voltage-Phase (60 Hz) | 208/230-1 |
Minimum Circuit Ampacity 5 | 23.4 |
Max. Overcurrent Protection 6 | 40 |
Min / Max Volts | 197/253 |
Electrical Conduit Size | ½" or ¾" |
Equipment Weight (lbs) | 260 |
Ship Weight (lbs) | 282 |
ENERGY STAR® Certified | YES |
Product Features
• Internal factory-installed thermal expansion valves for cooling and heat pump applications
• Direct drive, multi-speed ECM blower motor
• All-aluminum evaporator coil
• Coil mounting track for quick repositioning
• Optimized for use with R-410A refrigerant
• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard193
• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet
• Horizontal or vertical configuration capabilities
• 21” depth for easier attic access
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• Screw-less sides and back helps to reduce con- densation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Glue-less cabinet insulation retention
• Tool-less filter access
• Field Installed 3 kW – 25 kW electric heater kits available
AMST42CU1400
AMST42CU1400 | |
Nominal Ratings | |
Cooling (Btu/h) | 42,000 |
Blower | |
Diameter | 10" |
Width | 8" |
Coil Connections | |
Liquid | 3/8" |
Suction | 3/4” |
Coil Drain Connect (FPT) | 3/4” |
Electrical Data | |
Voltage | 208/230 |
Minimum Circuit Ampacity | 5.9/5.9 |
Max. Overcurrent Device (Amps) | 15/15 |
Minimum VAC | 197 |
Maximum VAC | 253 |
Blower Motor | |
Full Load Amps (FLA) | 4.7 |
Horsepower (HP) | ¾ |
Ship Weight (Lbs.) | 153 |
AMST42CU1400 Heat Kit Specs
Heater Kit Model | Circuit 1 | Circuit 2 | Single-Point Kit | |||||
Heater Amps | Mininum Circuit Ampacity 208/230 | Max Over Current Protection 208/230 | Heater Amps | Mininum Circuit Ampacity 208/230 | Max Over Current Protection 208/230 | Mininum Circuit Ampacity 208/230 | Max Over Current Protection 208/230 | |
AMST42CU1400 | 0/0 | 5.9/5.9 | 15/15 | |||||
3 KW | 10.8/12.5 | 19/21.5 | 20/25 | |||||
5 KW | 17.3/20 | 28/30.9 | 30/35 | |||||
6 KW | 21.7/25 | 33/37.1 | 35/40 | |||||
8 KW | 28.9/33.3 | 42/47.5 | 45/50 | |||||
10 KW | 34.7/40 | 49/55.9 | 50/60 | |||||
15 KW | 40 | 55.9 | 60 | 20 | 25 | 25 | 80.9 | 90 |
Product Documents
$4,010.00
Out of stock