STOREWIDE SALE ADD TO CART TO SEE SAVINGS

3 Ton 15.2 SEER2 Goodman Heat Pump Condensing Unit GSZH503610

Standard Features
• High-efficiency scroll compressor
• SmartShift® technology to ensure quiet reliable defrost
• Copper tube/ enhanced aluminum fin coil- 5mm diameter on 1.5-3.5T
• Factory-installed suction-line accumulator
• Factory-installed compressor crankcase heater
• Factory-installed high-capacity muffler
• High- and low-pressure switches
• Service valves with sweat connections and easy access to gauge ports
• Fully charged for 15’ of tubing length
• Contactor with lug connection
• Ground lug connection
• AHRI Certified; ETL Listed

Cabinet Features
• Removable grille style top design compliant with UL 60335-2-40
• Steel louver coil guard
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Top and side maintenance access
• Single panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for
hurricane-type winds
(Anchor bracket kits available.)

GSZH503610

  GSZH503610
Nominal Capacities  
Cooling (BTU/h)  36,000
Heating (BTU/h) 36,000
SEER2 15.2
Decibels 72
Compressor  
RLA   16
LRA    91.9
Stage  Single
Type Scroll
Condenser Fan Motor  
Horsepower 1/3
FLA 2.8
Refrigeration System  
Refrigerant Line Size¹  
Liquid Line Size (“O.D.) ⅜"
Suction Line Size (“O.D.) ⅞"
Refrigerant Connection Size  
Liquid Valve Size (“O.D.) ⅜"
Suction Valve Size (“O.D.) ⅞"
Valve Connection Type Sweat
Refrigerant Charge (oz.) 114
Electrical Data  
Volts/Phase (60 Hz) 208/230
Minimum Circuit Ampacity ²  
Max. Overcurrent Protection ³ 35
Min / Max Volts 197/253
Electrical Conduit Size 1/2" or 3/4"
Unit Weights  
Equipment Weight 222
Shipping Weight 242

¹ Tested and rated in accordance with AHRI Standard 210/240
² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs
will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
• Installation of these units requires the specified TXV Kit to be installed on the indoor coil.
THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.

$2,977.00

Availability: In stock

Frequently Bought Together

60 AMP NON-FUSED DISCONNECT BOX

WIRE WHIP 1/2"X6' #10

-

Scroll to Top