STOREWIDE SALE ADD TO CART TO SEE SAVINGS

2 Ton 15.2 SEER2 Goodman AC Split System GSXH502410+AMST24BU1400 (Not a Heat Pump)

2 Ton 15.2 SEER2 Goodman AC Split System GSXH502410+AMST24BU1400

 

GSXH502410

 

Standard Features
• High-efficiency scroll compressor
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

GSXH502410
Capacities
Nominal Cooling (BTU/h) 24,000
Decibels (dBA) 73
Compressor
RLA 11.5
LRA 59.5
Stage Single
Type Scroll
Condenser Fan Motor
Motor Type PSC
Horsepower
FLA 0.95
Refrigeration System
Refrigerant Line Size
Liquid Line Size (“O.D.) ⅜"
Suction Line Size (“O.D.) ¾"
Refrigerant Connection Size
Liquid Valve Size (“O.D.) ⅜"
Suction Valve Size (“O.D.) ¾"
Valve Type Sweat
Refrigerant Charge 72
Electrical Data
Voltage-Phase (60 Hz) 208/230-1
Minimum Circuit Ampacity 15.3
Max. Overcurrent Protection 25
Min / Max Volts 197/253
Electrical Conduit Size ½" or ¾"
Equipment Weight (lbs) 151
Ship Weight (lbs) 169

¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes,
refer to the Installation Instructions and/or the Long Line Set Applications guide.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

AMST24BU1400

 

Product Features
• Internal factory-installed thermal expansion valves for cooling and heat pump applications
• Direct drive, multi-speed ECM blower motor
• All-aluminum evaporator coil
• Coil mounting track for quick repositioning
• Optimized for use with R-410A refrigerant
• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard193
• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet
• Horizontal or vertical configuration capabilities
• 21” depth for easier attic access
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• Screw-less sides and back helps to reduce con- densation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Glue-less cabinet insulation retention
• Tool-less filter access
• Field Installed 3 kW – 25 kW electric heater kits available

 

AMST24BU1400

  AMST24BU14*
Nominal Ratings
Cooling (Btu/h) 24,000
Blower  
Diameter 10"
Width 6"
Coil Connections  
Liquid 3/8"
Suction 3/4"
Coil Drain Connect (FPT) 3/4”
Electrical Data  
Voltage 208/230
Minimum Circuit Ampacity 5.8/5.8
Max. Overcurrent Device (Amps) 15/15
Minimum VAC 197
Maximum VAC 253
Blower Motor  
Full Load Amps (FLA) 4.6
Horsepower (HP) ¾
Ship Weight (Lbs.) 112

AMST24BU1400 Heat Kit Specs

Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit
  Heater Amps Mininum Circuit Ampacity 208/230 Max Over Current Protection 208/230 Heater Amps Mininum Circuit Ampacity 208/230 Max Over Current Protection 208/230 Mininum Circuit Ampacity 208/230 Max Over Current Protection 208/230
AMST24BU1400 0/0 5.8/5.8 15/15          
3 KW 10.8/12.5 19/21.4 20/25          
5 KW 17.3/20 27/30.8 30/35          
6 KW 21.7/25 32.8/37 35/40          
8 KW 28.9/33.3 41.9/47 45/50          
10 KW 34.7/40 49.1/56 50/60          
15 KW 40 55.8 60 20 25 25 80.8 90

$3,160.00

Availability: In stock

Frequently Bought Together

Goodman HKSX05XC 5 kW Electric Heat Kit for Goodman Air Handlers 208-240/60/1

Goodman HKSX08XC 8 kW Electric Heat Kit for Goodman Air Handlers 208-240/60/1

Goodman HKSX10XC 10 kW Electric Heat Kit for Goodman Air Handlers 208-240/60/1

Goodman HKSC15XB 15 kW Electric Heat Kit with Breaker for Goodman Air Handlers 240/60/1

Safe-T-Switch SS2 Gen-3

60 AMP NON-FUSED DISCONNECT BOX

Out of stock

WIRE WHIP 3/4"X6' #8

Prostat Non-Programmable Thermostat 1 Heat / 1 Cool Conventional or Heat Pump

-

Scroll to Top