Start The Year Off With Huge Saving On Goodman's Seer2 Split Systems!

3 Ton 16 SEER Goodman A/C Straight Cool System GSX160361+ASPT47D14 Install Kit

Install Kit Includes:

* 30′ Copper Insulated Line Set
* Drain Float Switch
* 6′ Electrical Whip
* 60 amp non fused disconnect
* Plastic Condenser Pad
* Digital Thermostat
* Heat Strip up to 10 kw

 

Standard Features

• Energy-efficient compressor

• Factory-installed filter drier

• Fully charged for 15’ of tubing length

• Copper tube/aluminum fin coil

• Service valves with sweat connections and easy-to-access gauge ports

• Contactor with lug connection

• Ground lug connection

• AHRI Certified

• ETL Listed

Cabinet Features

• Heavy-gauge galvanized-steel cabinet with a louvered sound control top

• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval

• Wire fan discharge grille

• Steel louver coil guard

• Single-panel access to controls with space provided for field-installed accessories

• When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for
hurricane-type winds

(Anchor bracket kits available.)

GSX160361
Capacities
Nominal Cooling (BTU/h) 34,800
SEER 16
Decibels 71.5
Compressor
RLA 14.1
LRA 77
Condenser Fan Motor
Horsepower 1/6
FLA 0.95
Refrigeration System
Refrigerant Line Size ¹
Liquid Line Size (“O.D.) ⅜”
Suction Line Size (“O.D.) ⅞”
Refrigerant Connection Size
Liquid Valve Size (“O.D.) ⅜”
Suction Valve Size (“O.D.) ⅞”
Valve Type Sweat
Refrigerant Charge 94
Electrical Data
Voltage-Phase (60 Hz) 208/230-1
Minimum Circuit Ampacity ² 18.6
Max. Overcurrent Protection ³ 30
Min / Max Volts 197/253
Electrical Conduit Size ½” or ¾”
Equipment Weight (lbs) 162
Ship Weight (lbs) 180
ENERGY STAR® Certified  Yes

Product Features

• Internal factory-installed thermal expansion valves for cooling and heat pump applications

• Direct drive, multi-speed ECM blower motor

• All-aluminum evaporator coil

• Coil mounting track for quick repositioning

• Optimized for use with R-410A refrigerant

• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in

accordance with ASHRAE standard 193

• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in

accordance with ASHRAE standard 193

• AHRI certified; ETL listed

• Rigid SmartFrame™ cabinet

• Horizontal or vertical configuration capabilities

• 21” depth for easier attic access

• DecaBDE-free thermoplastic drain pan with secondary drain connections

• Screw-less sides and back helps to reduce condensation when installed in humid locations

• Foil-faced insulation covers the internal casing to reduce cabinet condensation

• Galvanized, leather grain-embossed finish

• Glue-less cabinet insulation retention

• Tool-less filter access

• Field Installed 3 kW – 25 kW electric heater

kits available

ASPT47D14
Nominal Ratings 42,000
Cooling (Btu/h)
Blower
Diameter 10⅝”
Width 10⅝”
Coil Connections
Liquid ⅜”
Suction ⅞”
Coil Drain Connect (FPT) ¾”
Electrical Data
Voltage 208/230
Minimum Circuit Ampacity 5.6 / 5.6
Max. Overcurrent Device (Amps) 15 / 15
Minimum VAC 197
Maximum VAC 253
Blower Motor
Full Load Amps (FLA) 4.5
Horsepower (HP) ¾
Ship Weight (Lbs.) 155

Prop 65 Warning:

Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information: www.P65Warnings.ca.gov

$3,837.00

-