<h3>3 Ton 14.3 SEER2 Goodman Heat Pump Condensing Unit GLZS4BA3610 R-32</h3>
<strong>Standard Features </strong>
<ul>
<li>High-efficiency compressor</li>
<li>SmartShift® technology to ensure quiet reliable defrost</li>
<li>Enhanced aluminum fin coil- 5 mm diameter on 1.5T-3.5 Ton</li>
<li>Enhanced aluminum fin coil with 7mm diameter copper tubes in 4.0- to 5.0-ton</li>
<li>Single-speed PSC condenser fan motor</li>
<li>Factory-installed bi-flow liquid-line filter drier</li>
<li>Factory-installed suction-line accumulator</li>
<li>Factory-installed compressor crankcase heater</li>
<li>Factory-installed high-capacity muffler</li>
<li>High- and low-pressure switches</li>
<li>Service valves with sweat connections and easy access to gauge ports</li>
<li>Fully charged for 15’ of tubing length</li>
<li>Fully enclosed contactor with lug connection</li>
<li>Ground lug connection</li>
<li>Capacitors with extended life</li>
<li>AHRI Certified; ETL Listed</li>
</ul>
<strong>Cabinet Features</strong>
<ul>
<li>Removable grille-style top design compliant with UL 60335-2-40</li>
<li>Steel louver coil guard</li>
<li>Heavy-gauge galvanized-steel cabinet</li>
<li>Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval</li>
<li>Top and side maintenance access</li>
<li>When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)</li>
</ul>
<ol>
<li>Tested and rated in accordance with ARI Standard 210/240</li>
<li>Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes</li>
<li>Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.</li>
</ol>
<strong>Notes</strong>
<ul>
<li>Always check the S&R plate for electrical data on the unit being installed.</li>
<li>Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.</li>
<li>Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.</li>
<li>Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.</li>
</ul>
<strong>Prop 65 Warning:</strong>
<p>Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information: <a href="https://www.P65Warnings.ca.gov" target="_blank">www.P65Warnings.ca.gov</a></p>