Goodman 4 Ton 17.2 SEER2 A/C Condenser GSXC704810 R-410a (Not a Heat Pump)

Goodman 4 Ton 17.2 SEER2 A/C Condenser GSXC704810 R-410a (Not a Heat Pump)

 

Standard Features
• Two-Stage Copeland Ultra-Tech scroll compressor
• Quiet two-speed ECM outdoor fan motor
• Integrated communicating ComfortBridge™ Technology
• Commissioning and diagnostics via Bluetooth indoor board via CoolCloud™ App
• Copeland® ComfortAlert™ built in diagnostics
• Copper tube/enhanced aluminum fin coil – 5mm on 2.0-3.0T
• Color-coded terminal strip for non-communicating set-up
• Only two low-voltage wires required in communication mode
• Factory-installed filter drier
• Factory-installed transformer
• Factory-installed high and low-pressure switches
• High-density foam compressor sound blanket
• Fully charged for 15’ of tubing length
• Ambient temperature sensors
• Ground lug connection
• AHRI Certified – ETL Listed

Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Venturi for increased velocity of airflow
• Heavy-gauge galvanized steel cabinet
• Baked-on powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard with rust-resistant screws.
• Top and side maintenance access
• Single-panel access to controls with space for field-installed accessories
• Service valves with sweat connections and easy-access gauge ports
• When properly anchored, meets the 2020 Florida Building Integrity requirements for hurricane-type winds
(Anchor bracket kits available.)

GSXC704810

  GSXC704810
Cooling Capacity  
Nominal Cooling (BTU/h) 48,000
Decibels (High/Low) 74
Compressor  
RLA 20.4
LRA 122.1
STAGE Two
TYPE Scroll
Condenser Fan Motor    
Motor Type  ECM
Horsepower (RPM) ⅓ 
FLA 2.8
Refrigeration System       
Refrigerant Line Size¹  
Liquid Line Size (“O.D.) ⅜"
Suction Line Size (“O.D.) 1⅛"
Refrigerant Connection Size  
Liquid Valve Size (“O.D.) ⅜"
Suction Valve Size (“O.D.") 2, 3 ⅞" 
Valve Connection Type Sweat
Refrigerant Charge4 195
Expansion Device TXV
Electrical Data    
Voltage-Phase-Hz 208/230-1
Minimum Circuit Ampacity 5 28.3
Max. Overcurrent Protection 6 45
 Min / Max Volts 197 / 253
Electrical Conduit Size ½" or ¾"
Equipment Weight (lbs) 276
Ship Weight (lbs) 298
ENERGY STAR® Certified ^ YES

^ Energy Star Notes
• Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched
with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov.
• The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR® requirements.
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes, refer to
the Installation Instructions and/or the Long Line Set Applications guide.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.