STOREWIDE SALE ADD TO CART TO SEE SAVINGS

Goodman 2 Ton 15.2 SEER2 A/C Straight Cool Condenser GSXH502410 R-410a

THIS IS NOT A HEAT PUMP CONDENSING UNIT.

GSXH502410

Standard Features
• High-efficiency scroll compressor
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

GSXH502410
Capacities
Nominal Cooling (BTU/h) 24,000
Decibels (dBA) 73
Compressor
RLA 11.5
LRA 59.5
Stage Single
Type Scroll
Condenser Fan Motor
Motor Type PSC
Horsepower
FLA 0.95
Refrigeration System
Refrigerant Line Size
Liquid Line Size (“O.D.) ⅜"
Suction Line Size (“O.D.) ¾"
Refrigerant Connection Size
Liquid Valve Size (“O.D.) ⅜"
Suction Valve Size (“O.D.) ¾"
Valve Type Sweat
Refrigerant Charge 72
Electrical Data
Voltage-Phase (60 Hz) 208/230-1
Minimum Circuit Ampacity 15.3
Max. Overcurrent Protection 25
Min / Max Volts 197/253
Electrical Conduit Size ½" or ¾"
Equipment Weight (lbs) 151
Ship Weight (lbs) 169

¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes,
refer to the Installation Instructions and/or the Long Line Set Applications guide.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

$1,954.00

Availability: In stock

Frequently bought together

60 AMP NON-FUSED DISCONNECT BOX

Out of stock

WIRE WHIP 1/2"X6' #10

-

Scroll to Top