- You cannot add "3 Ton 14 SEER Goodman HEAT PUMP Condenser GSZ140361 R410a" to the cart because the product is out of stock.
STOREWIDE SALE ADD TO CART TO SEE SAVINGS
Goodman 2 Ton 15.2 SEER2 A/C Straight Cool Condenser GSXH502410 R-410a
THIS IS NOT A HEAT PUMP CONDENSING UNIT.
GSXH502410
Standard Features
• High-efficiency scroll compressor
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
GSXH502410 | |
Capacities | |
Nominal Cooling (BTU/h) | 24,000 |
Decibels (dBA) | 73 |
Compressor | |
RLA | 11.5 |
LRA | 59.5 |
Stage | Single |
Type | Scroll |
Condenser Fan Motor | |
Motor Type | PSC |
Horsepower | ⅙ |
FLA | 0.95 |
Refrigeration System | |
Refrigerant Line Size | |
Liquid Line Size (“O.D.) | ⅜" |
Suction Line Size (“O.D.) | ¾" |
Refrigerant Connection Size | |
Liquid Valve Size (“O.D.) | ⅜" |
Suction Valve Size (“O.D.) | ¾" |
Valve Type | Sweat |
Refrigerant Charge | 72 |
Electrical Data | |
Voltage-Phase (60 Hz) | 208/230-1 |
Minimum Circuit Ampacity | 15.3 |
Max. Overcurrent Protection | 25 |
Min / Max Volts | 197/253 |
Electrical Conduit Size | ½" or ¾" |
Equipment Weight (lbs) | 151 |
Ship Weight (lbs) | 169 |
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes,
refer to the Installation Instructions and/or the Long Line Set Applications guide.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Product Documents
$1,954.00
Availability: In stock
-