- You cannot add "3 Ton 14 SEER Goodman HEAT PUMP Condenser GSZ140361 R410a" to the cart because the product is out of stock.
STOREWIDE SALE ADD TO CART TO SEE SAVINGS
1.5 Ton 14 SEER Goodman AC Straight Cool System GSX140191&ARUF25B14 R410a
(This Product Is Discontinued)
Standard Features
• Energy-efficient compressor
• Single-speed condenser fan motor
• Factory-installed filter drier
• Copper tube/aluminum fin coil
• Service valves with sweat connections
and easy-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge galvanized-steel cabinet with a louvered sound control top
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Top and side maintenance access
• Single-panel access to controls with space
provided for field-installed accessories
• When properly anchored, meets the 2010 Florida
Building Code unit integrity requirements for hurri-
cane-type winds (Anchor bracket kits available.)
GSX140191 | |
Capacities Max Cooling (BTU/h) |
18,000 |
SEER/EER | 14 / 12.2 |
Decibels | 71 |
Compressor | |
RLA | 9 |
LRA | 47.5 |
Condenser Fan Motor |
|
Hp | 1/8 |
FLA | 0.7 |
Refrigeration System Refrigerant Line Size ¹
|
|
Liquid Line Size (“O.D.) | ⅜” |
Suction Line Size (“O.D.) | ¾” |
Refrigerant Connection Size Liquid Valve Size (“O.D.) | ⅜” |
Suction Valve Size (“O.D.) ² ³ | ¾” |
Valve Type | Sweat |
Charge | 68 |
Included piston: | 0.053 |
Electrical Data |
|
Voltage-Phase (60 Hz) | 208/230-1 |
Minimum Circuit Ampacity ⁴ | 12 |
Max. Overcurrent Protection | 20 amps |
Min/Max Volts | 197/253 |
Conduit | ½” or ¾” |
Equipment Weight Shipping Weight |
131 146 |
Product Features
• Check flowrator for cooling and heat pump applications
• Direct drive, multi-speed PSC blower motor
• All-aluminum evaporator coil
• Coil mounting track for quick repositioning
• Cabinet air leakage less than 2.0% at
1.0 inch H₂O when tested in accordance with ASHRAE standard 193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in
accordance with ASHRAE standard 193
• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet
• Horizontal or vertical configuration capabilities
• 21″ depth for easier attic access
• DecaBDE-free thermoplastic drain pan with secondary drain connections
• Screw-less sides and back helps to reduce condensation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish
• Glue-less cabinet insulation retention
• Tool-less filter access
• Field Installed 3 kW – 25 kW electric heater
kits available
ARUF25B14 | |
Nominal Ratings | |
Cooling (Btu/h) | 24,000 |
Piston Size | 0.051 |
Blower | |
Diameter | 9½” |
Width | 6″ |
Coil Connections | |
Liquid | ⅜” |
Suction | ¾” |
Coil Drain Connect (FPT) | ¾” |
Electrical Data | |
Voltage | 208/230 |
Min Circuit Ampacity | 2.2/2.2 |
Max. Overcurrent Device (Amps) | 15/15 |
Minimum VAC | 197 |
Maximum VAC | 253 |
Blower Motor | |
Full Load Amps (FLA) | 1.75 |
Horsepower (HP) | ⅓ |
Ship Weight (Lbs.) | 100 |
$2,050.00
-