1.5 Ton 16 SEER Goodman Air Conditioner Condenser GSX160181 R410a

Standard Features

• Energy-efficient compressor

• Factory-installed filter drier

• Fully charged for 15’ of tubing length

• Copper tube/aluminum fin coil

• Service valves with sweat connections and easy-to-access gauge ports

• Contactor with lug connection

• Ground lug connection

• AHRI Certified

• ETL Listed

Cabinet Features

• Heavy-gauge galvanized-steel cabinet with a louvered sound control top

• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval

• Wire fan discharge grille

• Steel louver coil guard

• Single-panel access to controls with space provided for field-installed accessories

• When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for
hurricane-type winds

(Anchor bracket kits available.)

  GSX160181
Capacities  
Nominal Cooling (BTU/h) 18,000
SEER 16
Decibels 71.5
Compressor  
RLA 9.0
LRA 46
Condenser Fan Motor  
Horsepower 1/6
FLA 0.95
Refrigeration System  
Refrigerant Line Size ¹  
Liquid Line Size (“O.D.) ⅜”
Suction Line Size (“O.D.) ¾”
Refrigerant Connection Size  
Liquid Valve Size (“O.D.) ⅜”
Suction Valve Size (“O.D.) ¾”
Valve Type Sweat
Refrigerant Charge 78
Electrical Data  
Voltage-Phase (60 Hz) 208/230-1
Minimum Circuit Ampacity ² 12.2
Max. Overcurrent Protection ³ 20
Min / Max Volts 197/253
Electrical Conduit Size ½” or ¾”
Equipment Weight (lbs) 145
Ship Weight (lbs) 163
ENERGY STAR® Certified  Yes