2 Ton 14 SEER Goodman A/C Straight Cool GSX140241 & ARUF29B14 Install Kit 50'

SKU: GSX140241+ARUF29B14+HKSX05XC+IN50 Categories , Tags , , ,

Out of stock

$1,860.00
Call for Availability

Out of stock

Compare
SKU: GSX140241+ARUF29B14+HKSX05XC+IN50 Categories: , Tags: , , ,

Description

Install Kit Includes:

* 50′ Copper Insulated Line Set
* Drain Float Switch
* 6′ Electrical Whip
* 60 amp non fused disconnect
* Plastic Condenser Pad 
* Digital Thermostat
* Heat Strip up to 10 kw

 

Standard Features

  • Energy-efficient compressor
  • Single-speed condenser fan motor
  • Factory-installed filter drier
  • Copper tube/aluminum fin coil
  • Service valves with sweat connections and easy-access gauge ports
  • Contactor with lug connection
  • Ground lug connection
  • AHRI Certified; ETL Listed

Cabinet Features

  • Heavy-gauge galvanized-steel cabinet with a louvered sound control top
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Steel louver coil guard
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

 

 

GSX140241

Capacities

 

Max Cooling (BTU/h)

24,000

SEER/EER

14 / 12

Decibels

74

Compressor

 

RLA

7.7

LRA

38.0

Condenser Fan Motor

 

Hp

1/8

FLA

0.7

Refrigeration System

Refrigerant Line Size ¹

 

Liquid Line Size (“O.D.)

⅜”

Suction Line Size (“O.D.)

¾”

Refrigerant Connection Size

 

Liquid Valve Size (“O.D.)

⅜”

Suction Valve Size (“O.D.) ² ³

¾”

Valve Type

Sweat

Charge

72

Included piston:

0.057

Electrical Data

 

Voltage-Phase (60 Hz)

208/230-1

Minimum Circuit Ampacity ⁴

10.3

Max. Overcurrent Protection ⁵

15 amps

Min/Max Volts

197/253

Conduit

½” or ¾”

 

Product Features

-Check flowrator for cooling and heat pump applications

-Direct drive, multi-speed PSC blower motor   

-All-aluminum evaporator coil

-Coil mounting track for quick repositioning  

-Cabinet air leakage less than 2.0% at

1.0 inch  H₂O when tested in accordance 

with ASHRAE standard 193

-Cabinet air leakage less than 1.4%

at 0.5 inch H₂O when tested in

accordance with ASHRAE standard 193

-AHRI certified; ETL listed

-Tool-less filter access

-Field Installed 3 kW – 25 kW electric heater

kits available

-Rigid SmartFrame cabinet

-Horizontal or vertical configuration capabilities

-21″ depth for easier attic access

-DecaBDE-free thermoplastic drain

pan with secondary drain connections

-Screw-less sides and back helps to reduce

condensation when installed in humid locations

-Foil-faced insulation covers the internal 

 casing to reduce cabinet condensation

-Galvanized, leather grain-embossed finish

-Glue-less cabinet insulation retention 

 

 

 

ARUF29B14

Nominal Ratings

 

Cooling (Btu/h)

 25,000

Piston Size

0.057

Blower

 

Diameter

 9½”

Width

6″

Coil Connections

 

Liquid

 ⅜”

Suction

¾”

Coil Drain Connect (FPT)

¾”

Electrical Data

 

Voltage

 208/230

Min Circuit Ampacity

2.2/2.2

Max. Overcurrent Device (Amps)

15/15

Minimum VAC

197

Maximum VAC

253

Blower Motor

 

Full Load Amps (FLA)

 1.75

Horsepower (HP)

Ship Weight (Lbs.)

100

 