STOREWIDE SALE ADD TO CART TO SEE SAVINGS

Goodman 4 Ton 15.2 SEER2 A/C Straight Cool Condenser GSXH504810 R-410a

Goodman 4 Ton 15.2 SEER2 A/C Straight Cool Condenser GSXH504810 R-410a

THIS IS NOT A HEAT PUMP CONDENSING UNIT.

GSXH504810

Standard Features
• High-efficiency scroll compressor
• Factory-installed filter drier
• Fully charged for 15’ of tubing length
• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T
• Service valves with sweat connections and easy-to-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Removable grille-style top design compliant with UL 60335-2-40
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
• Steel louver coil guard
• Single-panel access to controls with space provided for field-installed accessories
• When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

GSXH504810

  GSXH504810
Capacities  
Nominal Cooling (BTU/h) 48,000
SEER2 15.2
Decibels (dBA) 73
Compressor  
RLA 19.9
LRA 110
Stage Single
Type Scroll
Condenser Fan Motor  
Motor Type PSC
Horsepower 1/4
FLA 1.30
Refrigeration System  
Refrigerant Line Size ¹  
Liquid Line Size (“O.D.) ⅜"
Suction Line Size (“O.D.) ⅞"
Refrigerant Connection Size  
Liquid Valve Size (“O.D.) ⅜"
Suction Valve Size (“O.D.) 2,3 ⅞"
Valve Type Sweat
Refrigerant Charge 4 180
Electrical Data  
Voltage-Phase (60 Hz) 208/230-1
Minimum Circuit Ampacity 5 26.2
Max. Overcurrent Protection 6 45
Min / Max Volts 197/253
Electrical Conduit Size ½" or ¾"
Equipment Weight (lbs) 260
Ship Weight (lbs) 282
ENERGY STAR® Certified YES

¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes,
refer to the Installation Instructions and/or the Long Line Set Applications guide.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment
procedure found in the Installation Instructions.
5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

SKU: GSXH504810 Categories , Tags ,

$2,806.00

Availability: In stock

Frequently bought together

60 AMP NON-FUSED DISCONNECT BOX

WIRE WHIP 3/4"X6' #8

-

Scroll to Top